Household
UF/UFL/UFT
From left
1st: Submersible pump
2nd: UFT type tank unit
3rd: UF type package unit
Selection chartNOTE Actual performance may slightly differ from the values in table and chart. Values in table show standard characteristics.
UF2
Total head(m)
Capacity(L/min)
Specificiation tableNOTE Actual performance may slightly differ from the values in table and chart. Values in table show standard characteristics.
50Hz
UF2 Capacity for low flow stop: 4L/min
25 100 UF2-450S UF2-450S US2-456T 450 Single phase 100V 7 32 40 30〈20〉[10] 14〈24〉[34] 27 10〈20〉[30] DL
25 100 UF2-450T UF2-450T US2-456T 450 Three phase 200V 7 32 40 30〈20〉[10] 14〈24〉[34] 27 10〈20〉[30] DL
25 100 UF2-600S UF2-600S US2-606T 600 Single phase 100V 8 38 47 35〈25〉[15] 16〈26〉[36] 31 12〈22〉[32] DL
25 100 UF2-600S2 UF2-600S2 US2-606T 600 Single phase 200V 8 38 47 35〈25〉[15] 16〈26〉[36] 31 12〈22〉[32] DL
25 100 UF2-600T UF2-600T US2-606T 600 Three phase 200V 8 38 47 35〈25〉[15] 16〈26〉[36] 31 12〈22〉[32] DL
25 100 UFH2-600S UF2-600S USH2-606T 600 Single phase 100V 10 24 62 50〈40〉[30] 16〈26〉[36] 20 12〈22〉[32] DL
25 100 UFH2-600S2 UF2-600S2 USH2-606T 600 Single phase 200V 10 24 62 50〈40〉[30] 16〈26〉[36] 20 12〈22〉[32] DL
25 100 UFH2-600T UF2-600T USH2-606T 600 Three phase 200V 10 24 62 50〈40〉[30] 16〈26〉[36] 20 12〈22〉[32] DL
25 100 UF2-900S2 UF2-900S2 US2-906 900 Single phase 200V 12 45 66 50〈40〉[30] 20〈30〉[40] 42 16〈26〉[36] DL
25 100 UF2-900 UF2-900 US2-906 900 Three phase 200V 12 45 66 50〈40〉[30] 20〈30〉[40] 42 16〈26〉[36] DL
25 100 UF2-1100S2 UF2-1100S2 US2-1106 1100 Single phase 200V 12 43 81 60〈50〉[40] 25〈35〉[45] 42 21〈31[〉41] DL
25 100 UF2-1100 UF2-1100 US2-1106 1100 Three phase 200V 12 43 81 60〈50〉[40] 25〈35〉[45] 42 21〈31[〉41] DL
Values enclosed in ( ) are for single phase 200V model. *Operation characteristics enclosed in < > shows the value when Fine sensor set at M, and [ ] shows the value when Fine sensor set at H.
* Reference
UF2 Capacity for low flow stop: 4L/min
25 100 UF2-450S UF2-450S US2-456T 450 Single phase 100V 7 8 131 30〈20〉[10] 14〈24〉[34] 7 10〈20〉[30] DL
25 100 UF2-450T UF2-450T US2-456T 450 Three phase 200V 7 8 131 30〈20〉[10] 14〈24〉[34] 7 10〈20〉[30] DL
25 100 UF2-600S UF2-600S US2-606T 600 Single phase 100V 8 10 154 35〈25〉[15] 16〈26〉[36] 8 12〈22〉[32] DL
25 100 UF2-600S2 UF2-600S2 US2-606T 600 Single phase 200V 8 10 154 35〈25〉[15] 16〈26〉[36] 8 12〈22〉[32] DL
25 100 UF2-600T UF2-600T US2-606T 600 Three phase 200V 8 10 154 35〈25〉[15] 16〈26〉[36] 8 12〈22〉[32] DL
25 100 UFH2-600S UF2-600S USH2-606T 600 Single phase 100V 10 6 203 50〈40〉[30] 16〈26〉[36] 5 12〈22〉[32] DL
25 100 UFH2-600S2 UF2-600S2 USH2-606T 600 Single phase 200V 10 6 203 50〈40〉[30] 16〈26〉[36] 5 12〈22〉[32] DL
25 100 UFH2-600T UF2-600T USH2-606T 600 Three phase 200V 10 6 203 50〈40〉[30] 16〈26〉[36] 5 12〈22〉[32] DL
25 100 UF2-900S2 UF2-900S2 US2-906 900 Single phase 200V 12 11 216 50〈40〉[30] 20〈30〉[40] 11 16〈26〉[36] DL
25 100 UF2-900 UF2-900 US2-906 900 Three phase 200V 12 11 216 50〈40〉[30] 20〈30〉[40] 11 16〈26〉[36] DL
25 100 UF2-1100S2 UF2-1100S2 US2-1106 1100 Single phase 200V 12 11 265 60〈50〉[40] 25〈35〉[45] 11 21〈31[〉41] DL
25 100 UF2-1100 UF2-1100 US2-1106 1100 Three phase 200V 12 11 265 60〈50〉[40] 25〈35〉[45] 11 21〈31[〉41] DL
Values enclosed in ( ) are for single phase 200V model. *Operation characteristics enclosed in < > shows the value when Fine sensor set at M, and [ ] shows the value when Fine sensor set at H.
* Reference
Selection chartNOTE Actual performance may slightly differ from the values in table and chart. Values in table show standard characteristics.
UFL2
Total head(m)
Capacity(L/min)
Specificiation tableNOTE Actual performance may slightly differ from the values in table and chart. Values in table show standard characteristics.
50Hz
UFL2 Capacity for low flow stop: 4L/min
32 100 UFL2-450S 450 Single phase 100V 4 72 22 12〈6〉 14〈20〉 53 10〈16〉 DL
32 100 UFL2-450T 450 Three phase 200V 4 72 22 12〈6〉 14〈20〉 53 10〈16〉 DL
32 100 UFL2-600S 600 Single phase 100V 5 85 24 12〈6〉 16〈22〉 73 12〈18〉 DL
32 100 UFL2-600S2 600 Single phase 200V 5 85 24 12〈6〉 16〈22〉 73 12〈18〉 DL
32 100 UFL2-600T 600 Three phase 200V 5 85 24 12〈6〉 16〈22〉 73 12〈18〉 DL
32 100 UFL2-900 900 Three phase 200V 8 100 32 18〈12〉 18〈24〉 95 14〈20〉 DL
32 100 UFL2-900S2 900 Single phase 200V 8 100 32 18〈12〉 18〈24〉 95 14〈20〉 DL
32 100 UFL2-1100 1100 Three phase 200V 8 100 41 24〈18〉 21〈27〉 95 17〈23〉 DL
32 100 UFL2-1100S2 1100 Single phase 200V 8 100 41 24〈18〉 21〈27〉 95 17〈23〉 DL
* Reference
UFL2 Capacity for low flow stop: 4L/min
32 100 UFL2-450S 450 Single phase 100V 4 19 72 12〈6〉 14〈20〉 14 10〈16〉 DL
32 100 UFL2-450T 450 Three phase 200V 4 19 72 12〈6〉 14〈20〉 14 10〈16〉 DL
32 100 UFL2-600S 600 Single phase 100V 5 22 78 12〈6〉 16〈22〉 19 12〈18〉 DL
32 100 UFL2-600S2 600 Single phase 200V 5 22 78 12〈6〉 16〈22〉 19 12〈18〉 DL
32 100 UFL2-600T 600 Three phase 200V 5 22 78 12〈6〉 16〈22〉 19 12〈18〉 DL
32 100 UFL2-900 900 Three phase 200V 8 26 104 18〈12〉 18〈24〉 25 14〈20〉 DL
32 100 UFL2-900S2 900 Single phase 200V 8 26 104 18〈12〉 18〈24〉 25 14〈20〉 DL
32 100 UFL2-1100 1100 Three phase 200V 8 26 134 24〈18〉 21〈27〉 25 17〈23〉 DL
32 100 UFL2-1100S2 1100 Single phase 200V 8 26 134 24〈18〉 21〈27〉 25 17〈23〉 DL
* Reference
Selection chartNOTE Actual performance may slightly differ from the values in table and chart. Values in table show standard characteristics.
UF2T
Total head(m)
Capacity(L/min)
Specificiation tableNOTE Actual performance may slightly differ from the values in table and chart. Values in table show standard characteristics.
50Hz
UF2T Capacity for low flow stop: 4L/min
25 UF2T-450S 450 Single phase 100V 7 32 41 45(35) 26 41(31) DL DL DL DL
25 UF2T-450T 450 Three phase 200V 7 32 41 45(35) 26 41(31) DL DL DL DL
25 UF2T-600S 600 Single phase 100V 8 48 41 45(35) 42 41(31) DL DL DL DL
25 UF2T-600T 600 Three phase 200V 8 48 41 45(35) 42 41(31) DL DL DL DL
Value enclosed in ( ) shows the specification when head is set at low (fine sensor set at L).
* Reference
UF2T Capacity for low flow stop: 4L/min
25 UF2T-450S 450 Single phase 100V 7 8 134 45(35) 6 41(31) DL DL DL DL
25 UF2T-450T 450 Three phase 200V 7 8 134 45(35) 6 41(31) DL DL DL DL
25 UF2T-600S 600 Single phase 100V 8 12 134 45(35) 11 41(31) DL DL DL DL
25 UF2T-600T 600 Three phase 200V 8 12 134 45(35) 11 41(31) DL DL DL DL
Value enclosed in ( ) shows the specification when head is set at low (fine sensor set at L).
* Reference