page top

Kawamoto Pump Mfg. Co., Ltd.

Special purpose

NFG



Selection chartNOTEActual performance may slightly differ from the values in table and chart. Values in table show standard characteristics.

60Hz

Unit conversion calculator

NOTE
This is the only calculator for unit conversion. Graph will be not affected by this conversion.

Capacity: Q


 → 
Total head: H


 → 
Discharge head(m)
Capacity(L/min)


Specificiation tableNOTEActual performance may slightly differ from the values in table and chart. Values in table show standard characteristics.

60Hz

NFG2-

in case -2m total suction head, small water amount stop rate: 4L/min

BoreOperation methodRef.ModelMotorPower sourceHQoperation characteristics, Operation headoperation characteristics, Capacity *operation characteristics, Starting headCAD
Download
mmWVmℓ/minmℓ/minm
20Individual1NFG2-150S150Single phase 100V2019221418DL
25Individual2NFG2-250S250Single phase 100V2227242520DL
25Individual3NFG2-400S400Single phase 100V2534273123DL
25Individual3NFG2-400T400Three phase 200V2534273123DL
32Individual4NFG2-750750Three phase 200V2854304926DL
32Alternate5NFG2-400SH-A400Single phase 100V2533273023DL
32Alternate5NFG2-400TH-A400Three phase 200V2533273023DL
32Alternate6NFG2-750H-A750Three phase 200V2853304926DL
32Alternate & Parallel7NFG2-400SH-P400Single phase 100V2566276023DL
32Alternate & Parallel7NFG2-400TH-P400Three phase 200V2566276023DL
32Alternate & Parallel8NFG2-750H-P750Three phase 200V28106309826DL

* Reference