page top

Kawamoto Pump Mfg. Co., Ltd.

Sea water

KZB



Selection chartNOTEActual performance may slightly differ from the values in table and chart. Values in table show standard characteristics.

60Hz

Unit conversion calculator

NOTE
This is the only calculator for unit conversion. Graph will be not affected by this conversion.

Capacity: Q


 → 
Total head: H


 → 
Total head(m)
Capacity(m3/min)

1) Total head shows the value subtracted by the pressure loss of such like check valve from pump head. 2) Starting head is the value in case inflow suction (0m). 3) When changing the starting head, always set within selectable range of starting head.


Specificiation tableNOTEActual performance may slightly differ from the values in table and chart. Values in table show standard characteristics.

60Hz

Unit BoreSuction boreOperation methodRef.ModelMotorQHStarting headStop pressureAdjustable range of starting pressureAccumulator charged pressureMax. sound noise*2CAD
Download
mmmmkWm3/minmmMPaMPaMPadB
4040Individual1KZB406SE0.750.750.125160.160.230.10.0950DL
4040Individual2KZB406SE1.51.50.165280.270.380.210.255DL
4050Individual3KZB506SE1.51.50.23200.20.270.120.1452DL
4050Individual4KZB506SE2.22.20.25280.270.370.210.255DL
4040Alternate5KZB406AE0.750.750.125160.160.230.10.0950DL
4040Alternate6KZB406AE1.51.50.165280.270.380.210.255DL
4050Alternate7KZB506AE1.51.50.23200.20.270.120.1452DL
4050Alternate8KZB506AE2.22.20.25280.270.370.210.255DL
5040Alternate & Parallel9KZB406PE0.750.75X20.25160.160.230.10.0953DL
5040Alternate & Parallel10KZB406PE1.51.5X20.33280.270.380.210.258DL
6550Alternate & Parallel11KZB506PE1.51.5X20.46200.20.270.120.1455DL
6550Alternate & Parallel12KZB506PE2.22.2X20.5280.270.370.210.258DL

*1 Min. starting pressure adjustable from default starting pressure

*2 Operation sound is the value of the duty point in the standard specification.

NOTE) If planning to use a device with rapid change of flow rate such as a flash valve, consult us.