page top

Kawamoto Pump Mfg. Co., Ltd.

Sea water

KZB



Selection chartNOTEActual performance may slightly differ from the values in table and chart. Values in table show standard characteristics.

50Hz

Unit conversion calculator

NOTE
This is the only calculator for unit conversion. Graph will be not affected by this conversion.

Capacity: Q


 → 
Total head: H


 → 
Total head(m)
Capacity(m3/min)

1) Total head shows the value subtracted by the pressure loss of such like check valve from pump head. 2) Starting head is the value in case inflow suction (0m). 3) When changing the starting head, always set within selectable range of starting head.


Specificiation tableNOTEActual performance may slightly differ from the values in table and chart. Values in table show standard characteristics.

50Hz

Unit BoreSuction boreOperation methodRef.ModelMotorQHStarting pressureStop pressureAdjustable range of starting pressureAccumulator charged pressureMax. sound noise*2CAD
Download
mmmmkWm3/minmmMPaMPaMPadB
4040Individual1KZB405SE0.750.750.135160.160.230.090.0948DL
4040Individual2KZB405SE1.51.50.16280.270.350.20.253DL
4050Individual3KZB505SE1.51.50.23200.20.270.140.1450DL
4050Individual4KZB505SE2.22.20.25280.270.370.20.258DL
4040Alternate5KZB405AE0.750.750.135160.160.230.090.0948DL
4040Alternate6KZB405AE1.51.50.16280.270.350.20.253DL
4050Alternate7KZB505AE1.51.50.23200.20.270.140.1450DL
4050Alternate8KZB505AE2.22.20.25280.270.370.20.258DL
5040Alternate & Parallel9KZB405PE0.750.75X20.27160.160.230.090.0950DL
5040Alternate & Parallel10KZB405PE1.51.5X20.32280.270.350.20.256DL
6550Alternate & Parallel11KZB505PE1.51.5X20.46200.20.270.140.1452DL
6550Alternate & Parallel12KZB505PE2.22.2X20.5280.270.370.20.261DL

*1 Min. starting pressure adjustable from default starting pressure

*2 Operation sound is the value of the duty point in the standard specification.

NOTE) If planning to use a device with rapid change of flow rate such as a flash valve, consult us.