page top

Kawamoto Pump Mfg. Co., Ltd.

Sea water

GSZB



Selection chartNOTEActual performance may slightly differ from the values in table and chart. Values in table show standard characteristics.

50Hz

Unit conversion calculator

NOTE
This is the only calculator for unit conversion. Graph will be not affected by this conversion.

Capacity: Q


 → 
Total head: H


 → 
Total head(m)
Capacity(m3/min)

1) Total head shows the value subtracted by the pressure loss of such like check valve from pump head. 2) Total head includes 6m suction total head. 3) When changing the starting head, always set within selectable range of starting head.


Specificiation tableNOTEActual performance may slightly differ from the values in table and chart. Values in table show standard characteristics.

50Hz

Capacity for low flow stop: 10L/min

Unit BoreSuction boreOperation methodRef.ModelMotorQHBoost up headSuction heightAdjustable range of starting pressureAccumulator charged pressureMax. sound noise*CAD
Download
mmmmkWm3/minmmmMPaMPadB
4040Individual1GSZB2-405SE1.51.50.15221660.1~0.250.0952DL
4040Alternate2GSZB2-405AE1.51.50.15221660.1~0.250.0952DL
5040Alternate & Parallel3GSZB2-405PE1.51.5X20.3221660.1~0.250.0959DL

NOTE1) If planning to use a device with rapid change of flow rate such as a flash valve, consult us.

NOTE 2) Starting head is set at the boost up head in standard specification.

*Operation sound is measured in operating at Max. capacity in standard specification with -1m suction head.