Kawamoto Pump Mfg. Co., Ltd.

Direct connecting

KDP-W



Selection chartNOTEActual performance may slightly differ from the values in table and chart. Values in table show standard characteristics.

50Hz

Unit conversion calculator

NOTE
This is the only calculator for unit conversion. Graph will be not affected by this conversion.

Capacity: Q


 → 
Total head: H


 → 
Total head(m)
Capacity(m3/min)

Total head shows the value which is subtracted by pressure loss in the pump unit exclude back flow preventer loss.


Specificiation tableNOTEActual performance may slightly differ from the values in table and chart. Values in table show standard characteristics.

50Hz

Stop flow rate:10L/min

Unit BoreSuction boreOperation methodRef.ModelMotorPower sourceQHStarting headAdjustable discharge pressure rangeAccumulator charged pressureOperation sound pressureCAD
Download
mmmmkWVm3/minmmmMPadB(A)
3232Alternate2KDP3-32A0.75S2WA0.75Single phase 200V0.08312420~310.1440~42DL
3232Alternate2KDP3-32A0.75WA0.75Single phase 200V0.08312420~310.1440~42DL
3232Alternate4KDP3-32A1.1S2WA1.1Three phase 200V0.08534434~530.2540~43DL
3232Alternate4KDP3-32A1.1WA1.1Three phase 200V0.08534434~530.2540~43DL
3232Alternate6KDP3-32A1.5WA1.5Three phase 200V0.1605041~600.2939~43DL
3232Alternate8KDP3-32A2.2WA2.2Three phase 200V0.1766460~760.4540~42DL
4040Alternate10KDP3-40A0.75S2WA0.75Single phase 200V0.18201410~200.0739~41DL
4040Alternate10KDP3-40A0.75WA0.75Three phase 200V0.18201410~200.0739~41DL
4040Alternate12KDP3-40A1.1S2WA1.1Single phase 200V0.15342716~340.1240~42DL
4040Alternate12KDP3-40A1.1WA1.1Three phase 200V0.15342716~340.1240~42DL
4040Alternate14KDP3-40A1.5WA1.5Three phase 200V0.17423418~420.1641~43DL
4040Alternate16KDP3-40HA1.5WA1.5Three phase 200V0.1605041~600.2939~43DL
4040Alternate18KDP3-40A2.2WA2.2Three phase 200V0.16665529~660.2740~44DL
4040Alternate20KDP3-40HA2.2WA2.2Three phase 200V0.1766460~750.4540~42DL
4040Alternate22KDP3-40A3.7WA3.7Three phase 200V0.2766450~760.3741~44DL
4040Alternate24KDP3-40A5.5WA5.5Three phase 200V0.26766460~750.3246~48DL
5050Alternate26KDP3-50A1.1S2WA1.1Single phase 200V0.15342716~340.1240~42DL
5050Alternate26KDP3-50A1.1WA1.1Three phase 200V0.15342716~340.1240~42DL
5050Alternate28KDP3-50A1.5WA1.5Three phase 200V0.17423414~420.1637~44DL
5050Alternate30KDP3-50HA1.5WA1.5Three phase 200V0.1605041~600.2939~43DL
5050Alternate32KDP3-50A2.2WA2.2Three phase 200V0.225393111~390.1439~45DL
5050Alternate34KDP3-50HA2.2WA2.2Three phase 200V0.16665529~660.2740~44DL
5050Alternate36KDP3-50A3.7WA3.7Three phase 200V0.25584823~580.2540~45DL
5050Alternate28KDP3-50HA3.7WA5.5Three phase 200V0.2766450~760.3741~44DL
5050Alternate40KDP3-50A5.5WA5.5Three phase 200V0.26766444~760.3246~48DL
5050Alternate42KDP3-50A7.5WA7.5Three phase 200V0.35766456~760.4246~48DL

NOTE1) If planning to use a device with rapid change of flow rate such as a flash valve, consult us.

NOTE 2) If obliged to install the booster pump at the long distance from water main, please consult us.

* Operation sound is the value from zero discharge to the standard specification.