page top

Kawamoto Pump Mfg. Co., Ltd.

Centrifugal

GES-2M



Selection chartNOTEActual performance may slightly differ from the values in table and chart. Values in table show standard characteristics.

50Hz

Unit conversion calculator

NOTE
This is the only calculator for unit conversion. Graph will be not affected by this conversion.

Capacity: Q


 → 
Total head: H


 → 
Total head(m)
Capacity(m3/min)


Specificiation tableNOTEActual performance may slightly differ from the values in table and chart. Values in table show standard characteristics.

50Hz

GES-2M

BoreRef.ModelMotorQHQHMax. back pressureCAD
Download
mmkWm3/minmm3/minmMPa
40X321GES405M2ME0.750.750.05170.211.50.8DL
40X322GES405M2ME1.51.50.0529.50.221.50.68DL
40X323GES405M2ME2.22.20.0535.50.2270.62DL
50X404GES505M2ME1.51.50.1220.32170.75DL
50X405GES505M2ME2.22.20.1300.3219.50.67DL
50X406GES505M2ME3.73.70.1440.32360.54DL
50X407GES505M2ME5.55.50.1550.3247.50.42DL
65X508GES655M2ME3.73.70.230.50.63220.68DL
65X509GES655M2ME5.55.50.240.50.63310.58DL
65X5010GES655M2ME7.57.50.2500.6341.50.48DL