Special purpose
RCA
From left
1st: Manual type (Floor mount)
2nd: Automatic type
3rd: Automatic alternate type
4th: Manual type (Pedestal support type)
Application
- Dirty coolant transfer to filtration device from machine tool
Feature
- Adopting Impeller made of sintered metal, abrasion-resistance is excellent.
- Mechanical seal-less structure prevents fluid from scattering by mechanical seal fracture.
- Due to dual rated voltage motor, one unit pump is available for both 200V class and 400V class. (with rewiring terminal)
- Terminal box position is changeable by rearranging the motor frame.
Standard spec
- Application liquid
- Fluid quality: Coolant, and so on * Cannot be used for clean water
Fluid temperature: 0~40°C
- Max. working viscosity
- 75mm2/s or less
- Motor
- Type: TEFC outdoor
Power source: 2 poles, Three phase 200V/400V
- Installation location
- Indoor, vertical installation (Horizontal installation is not available)
- Environmental condition
- temperature: 0~40°C
Humidity: 85%RH or less (No condensation)
Standard Accessories
-
Optional Accessories
-