page top

Kawamoto Pump Mfg. Co., Ltd.

Package booster

KVF


Selection chartNOTEActual performance may slightly differ from the values in table and chart. Values in table show standard characteristics.

60Hz

Unit conversion calculator

NOTE
This is the only calculator for unit conversion. Graph will be not affected by this conversion.

Capacity: Q


 → 
Total head: H


 → 

Suction bore: 50mm

Total head(m)
Capacity(m3/min)


Specificiation tableNOTEActual performance may slightly differ from the values in table and chart. Values in table show standard characteristics.

60Hz

Suction bore: 50mm

Capacity for low flow stop: 10L/min

Unit BoreSuction boreOperation methodRef.ModelMax. simultaneous operation Q'ty *1QQ : Non stand-by unit *2HAdjustable range of set headCAD
Download
mmmmkWm3/minm3/minmm
80502 units rotary1KVF2-50R2-11110.20.416585~165DL
80502 units rotary2KVF2-50R2-15150.20.4200140~200DL
80502 units rotary3KVF2-50R2-1818.50.230.46230180~230DL
80503 units rotary4KVF2-50R3-1111X20.40.616585~165DL
80503 units rotary5KVF2-50R3-1515X20.40.6200140~200DL
80503 units rotary6KVF2-50R3-1818.5X20.460.69230180~230DL
100504 rotary7KVF2-50R4-1111X30.60.816585~165DL
100504 rotary8KVF2-50R4-1515X30.60.8200140~200DL
100504 rotary9KVF2-50R4-1818.5X30.690.92230180~230DL
125505 rotary10KVF2-50R5-1111X40.8116585~165DL
125505 rotary11KVF2-50R5-1515X40.81200140~200DL
125505 rotary12KVF2-50R5-1818.5X40.921.15230180~230DL
125506 rotary13KVF2-50R6-1111X511.216585~165DL
125506 rotary14KVF2-50R6-1515X511.2200140~200DL
125506 rotary15KVF2-50R6-1818.5X51.151.38230180~230DL

*1 Standard

*2 Special specification