NOTE
This is the only calculator for unit conversion. Graph will be not affected by this conversion.
1) Total head shows the value subtracted by the pressure loss of such like check valve from pump head. 2) When changing the set head, always set within adjustable range. Adjust the starting head according to the set head. 3) Use pump within the specified
Max. 2 units simultaneous operation (2/3 rotary)
Unit Bore | Discharge bore | Operation method | Ref. | Model | Max. simultaneous operation Q'ty | Q | H | Starting pressure | Adjustable range of set head | Accumulator charged pressure | Operation sound | Power factor | CAD Download |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
mm | mm | ― | ― | ― | kW | m3/min | m | Mpa | m | MPa | dB(A) | % | ― |
65 | 32 | 3 units rotary | 1 | KF2-32R3E0.75 | 0.75X2 | 0.13 | 32 | 0.25 | 20~32 | 0.19 | 46~53 | 90.7 | DL |
65 | 32 | 3 units rotary | 2 | KF2-32R3E1.1 | 1.1X2 | 0.12 | 53 | 0.43 | 30~53 | 0.33 | 48~54 | 91.5 | DL |
65 | 32 | 3 units rotary | 3 | KF2-32R3E1.9 | 1.9X2 | 0.12 | 65 | 0.54 | 44~65 | 0.42 | 48~58 | 89.9 | DL |
80 | 40 | 3 units rotary | 4 | KF2-40R3E1.5 | 1.5X2 | 0.28 | 32 | 0.25 | 20~32 | 0.19 | 49~55 | 92.5 | DL |
80 | 40 | 3 units rotary | 5 | KF2-40R3E2.2 | 2.2X2 | 0.28 | 48 | 0.38 | 30~48 | 0.29 | 49~55 | 91.6 | DL |
80 | 40 | 3 units rotary | 6 | KF2-40R3E3.7 | 3.7X2 | 0.32 | 65 | 0.54 | 48~65 | 0.42 | 55~59 | 90.3 | DL |
80 | 40 | 3 units rotary | 7 | KF2-40R3E5.5 | 5.5X2 | 0.41 | 80 | 0.67 | 60~80 | 0.58 | 55~62 | 91.4 | DL |
100 | 50 | 3 units rotary | 8 | KF2-50R3E2.2 | 2.2X2 | 0.4 | 32 | 0.25 | 20~32 | 0.19 | 52~57 | 91.6 | DL |
100 | 50 | 3 units rotary | 9 | KF2-50R3E3.7 | 3.7X2 | 0.47 | 48 | 0.38 | 30~48 | 0.29 | 54~58 | 90.3 | DL |
100 | 50 | 3 units rotary | 10 | KF2-50R3E5.5 | 5.5X2 | 0.5 | 70 | 0.58 | 44~70 | 0.5 | 58~63 | 91.4 | DL |
100 | 50 | 3 units rotary | 11 | KF2-50R3E7.5 | 7.5X2 | 0.6 | 80 | 0.67 | 60~80 | 0.58 | 58~66 | 92.7 | DL |
125 | 65 | 3 units rotary | 12 | KF2-65R3E3.7 | 3.7X2 | 0.76 | 32 | 0.25 | 20~32 | 0.19 | 54~59 | 90.3 | DL |
125 | 65 | 3 units rotary | 13 | KF2-65R3E5.5 | 5.5X2 | 0.66 | 48 | 0.38 | 30~48 | 0.32 | 58~53 | 91.4 | DL |
125 | 65 | 3 units rotary | 14 | KF2-65R3E7.5 | 7.5X2 | 0.76 | 60 | 0.49 | 44~60 | 0.42 | 58~65 | 92.7 | DL |
NOTE) If planning to use a device with rapid change of flow rate such as a flash valve, consult us.
* Operation sound is the value from zero discharge to the standard specification. (reference)