NOTE
This is the only calculator for unit conversion. Graph will be not affected by this conversion.
Total head shows the value which is subtracted by pressure loss in the pump unit exclude back flow preventer loss.
Stop flow rate:10L/min
Unit Bore | Suction bore | Operation method | Ref. | Model | Motor | Power source | Q | H | Starting head | Adjustable discharge pressure range | Accumulator charged pressure | Operation sound pressure | CAD Download |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
mm | mm | ― | ― | ― | kW | v | m3/min | m | m | m | MPa | dB(A) | ― |
32 | 32 | Alternate | 1 | KDP3-32A0.75DA | 0.75 | Three phase 200V | 0.08 | 31 | 24 | 20~31 | 0.14 | 40~42 | DL |
32 | 32 | Alternate | 1 | KDP3-32A0.75S2DA | 0.75 | Single phase 200V | 0.08 | 31 | 24 | 20~31 | 0.14 | 40~42 | DL |
32 | 32 | Alternate | 3 | KDP3-32A1.1DA | 1.1 | Three phase 200V | 0.08 | 53 | 44 | 34~53 | 0.25 | 40~43 | DL |
32 | 32 | Alternate | 3 | KDP3-32A1.1S2DA | 1.1 | Single phase 200V | 0.08 | 53 | 44 | 34~53 | 0.25 | 40~43 | DL |
32 | 32 | Alternate | 5 | KDP3-32A1.5DA | 1.5 | Three phase 200V | 0.1 | 60 | 50 | 41~60 | 0.29 | 39~43 | DL |
32 | 32 | Alternate | 7 | KDP3-32A2.2DA | 2.2 | Three phase 200V | 0.1 | 76 | 64 | 60~76 | 0.45 | 40~42 | DL |
40 | 40 | Alternate | 9 | KDP3-40A0.75DA | 0.75 | Three phase 200V | 0.18 | 20 | 14 | 10~20 | 0.07 | 39~41 | DL |
40 | 40 | Alternate | 9 | KDP3-40A0.75S2DA | 0.75 | Single phase 200V | 0.18 | 20 | 14 | 10~20 | 0.07 | 39~41 | DL |
40 | 40 | Alternate | 11 | KDP3-40A1.1DA | 1.1 | Three phase 200V | 0.15 | 34 | 27 | 16~34 | 0.12 | 40~42 | DL |
40 | 40 | Alternate | 11 | KDP3-40A1.1S2DA | 1.1 | Single phase 200V | 0.15 | 34 | 27 | 16~34 | 0.12 | 40~42 | DL |
40 | 40 | Alternate | 13 | KDP3-40A1.5DA | 1.5 | Three phase 200V | 0.17 | 42 | 34 | 14~42 | 0.16 | 41~43 | DL |
40 | 40 | Alternate | 15 | KDP3-40HA1.5DA | 1.5 | Three phase 200V | 0.1 | 60 | 50 | 41~60 | 0.29 | 39~43 | DL |
40 | 40 | Alternate | 17 | KDP3-40A2.2DA | 2.2 | Three phase 200V | 0.16 | 66 | 55 | 29~66 | 0.27 | 40~44 | DL |
40 | 40 | Alternate | 19 | KDP3-40HA2.2DA | 2.2 | Three phase 200V | 0.1 | 76 | 64 | 60~76 | 0.45 | 40~42 | DL |
40 | 40 | Alternate | 21 | KDP3-40A3.7DA | 3.7 | Three phase 200V | 0.2 | 76 | 64 | 50~76 | 0.37 | 41~44 | DL |
40 | 40 | Alternate | 23 | KDP3-40A5.5DA | 5.5 | Three phase 200V | 0.26 | 76 | 64 | 60~76 | 0.32 | 46~48 | DL |
50 | 50 | Alternate | 25 | KDP3-50A1.1DA | 1.5 | Three phase 200V | 0.15 | 34 | 27 | 16~34 | 0.12 | 40~42 | DL |
50 | 50 | Alternate | 25 | KDP3-50A1.1S2DA | 1.5 | Single phase 200V | 0.15 | 34 | 27 | 16~34 | 0.12 | 40~42 | DL |
50 | 50 | Alternate | 25 | KDP3-50A1.5DA | 1.5 | Three phase 200V | 0.17 | 42 | 34 | 14~42 | 0.16 | 37~44 | DL |
50 | 50 | Alternate | 25 | KDP3-50HA1.5DA | 1.5 | Three phase 200V | 0.1 | 50 | 50 | 41~60 | 0.29 | 39~43 | DL |
50 | 50 | Alternate | 25 | KDP3-50A2.2DA | 2.2 | Three phase 200V | 0.225 | 39 | 31 | 11~39 | 0.14 | 39~45 | DL |
50 | 50 | Alternate | 25 | KDP3-50HA2.2DA | 2.2 | Three phase 200V | 0.16 | 66 | 55 | 29~66 | 0.27 | 40~44 | DL |
50 | 50 | Alternate | 25 | KDP3-50A3.7DA | 3.7 | Three phase 200V | 0.25 | 58 | 48 | 23~58 | 0.25 | 40~45 | DL |
50 | 50 | Alternate | 25 | KDP3-50HA3.7DA | 3.7 | Three phase 200V | 0.2 | 76 | 64 | 50~76 | 0.37 | 41~44 | DL |
50 | 50 | Alternate | 25 | KDP3-50A5.5DA | 5.5 | Three phase 200V | 0.26 | 76 | 64 | 44~76 | 0.32 | 46~48 | DL |
50 | 50 | Alternate | 25 | KDP3-50A7.5DA | 7.5 | Three phase 200V | 0.35 | 76 | 64 | 56~76 | 0.42 | 46~48 | DL |
NOTE1) If planning to use a device with rapid change of flow rate such as a flash valve, consult us.
NOTE 2) If obliged to install the booster pump at the long distance from water main, please consult us.
* Operation sound is the value from zero discharge to the standard specification.