NOTE
This is the only calculator for unit conversion. Graph will be not affected by this conversion.
Use broken line for the pump selection. -----20K -----10K
Bore | Model | Motor | Q | H | Adjust pressure of adjusting valve | Pressure switch: Standard setting | Default stop pressure | Min. adjustable start pressure | Min. adjustable stop pressure | CAD Download |
---|---|---|---|---|---|---|---|---|---|---|
mm | ― | kW | m3/min | m | MPa | MPa | MPa | MPa | MPa | ― |
15 | DPK2-15E10K | 1.5 | 18 | 100 | 1.37 | 0.98 | 1.18 | 0.265 | 0.49 | DL |
15 | DPK2-155BE10K | 2.2 | 25 | 100 | 1.37 | 0.98 | 1.18 | 0.265 | 0.49 | DL |
15 | DPK2-15E20K | 1.5 | 18 | 200 | 2.74 | 1.96 | 2.29 | 0.98 | 1.18 | DL |
15 | DPK2-155BE20K | 2.2 | 25 | 200 | 2.74 | 1.96 | 2.29 | 0.98 | 1.18 | DL |